Mean intraoperative time-weighted average core temperatures were no different, and significantly noninferior, with underbody resistive heating in comparison with upper-body forced-air warming.
Underbody resistive heating may be an alternative to forced-air warming.
2011-10-24
Eng.
Anesthesia and analgesia
Department of Outcomes Research, Cleveland Clinic, 9500 Euclid Avenue/P77, Cleveland, OH 44195, USA.
Anesth Analg. 2011 Nov;113(5):1076-81